0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessHome-based rehabilitation with robot assistance may significantly reduce therapist workload and facilitate post-stroke patient training. However, the lack of real-time therapist supervision requires higher safety, ease of use, and training efficiency of the rehabilitation system. Therefore, active robot rehabilitation systems may not be particularly ideal for home use due to high costs, large footprints, safety concerns, and the potential for motor slacking. Self-powered robots provide a promising alternative by enabling the unimpaired side (UIS) to assist the impaired side (IS) without external power. However, constant and rigid coupling between limbs may lead to the over-compensation by the UIS, reduce engagement of the IS, and fail to provide sufficient information for task performance assessment. This paper demonstrates a home-based self-powered rehabilitation system with a variable stiffness mechanism (VSM), providing proper coupling stiffness between the UIS and IS according to the IS's motor ability. The application of the VSM also allows for the measurement of motion errors and interaction forces using only encoders, facilitating motor ability evaluation and training task guidance. First, we propose a cable-driven VSM with active and passive stiffness regulation, and develop a bilateral two-degree-of-freedom rehabilitation system with the VSM for evaluation. Then, the system's functionality and efficacy are validated through experiments with twelve healthy subjects and ten stroke survivors. The proposed self-powered system can potentially avoid UIS's over-compensation, enhances IS's engagement, and improves training efficiency, while ensuring safety and reliability within home-based rehabilitation.
Ke Shi, Y. Gao, Maozeng Zhang, Lifeng Zhu, Aiguo Song (2025). A Home-Based Self-Powered Rehabilitation System with Variable Stiffness Mechanism. , 33, DOI: https://doi.org/10.1109/tnsre.2025.3582255.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2025
Authors
5
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1109/tnsre.2025.3582255
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access