0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessThe purpose of this study is to examine the effect of air change rate (ACH) on reducing particle concentration in a patient ward using numerical simulation. A patient ward is a large room or space in a medical facility where individuals with similar health conditions or treatments are grouped. It is equipped with modern beds, medical care systems, lighting, and ventilation systems to maintain a high level of hygiene. Airborne transmission in patient wards can easily spread to other individuals. Therefore, the ACH in the patient ward needs to be increased. Three ACH cases were investigated along with a baseline case using a simplified CFD model. The patient ward model was constructed and validated based on past literature. The Renormalization Group (RNG) k-epsilon turbulence model was selected to simulate airflow velocity in the patient ward. The movement of airborne particles was simulated using the Discrete Phase Model (DPM). An effective ACH was determined from the three cases. Based on the results, the most effective ACH in reducing particle dispersion in the patient ward was identified. The findings indicate that in Case 3, where ACH = 25h-1 and the ventilation opening size was 1 m × 1 m, the high airflow velocity in the patient ward completely reduced airborne particle concentration (100%) above patient 1 and 100% around other patients and medical staff. By reducing particle concentration, the number of particles that could infect other patients was also significantly reduced.
Syie Luing Wong, Huiyi Tan, Hong Yee Kek, Mohd Hafiz Dzarfan Othman, Poj Tangamchit, Nurfaezah Abdullah, KENG YINN WONG (2025). UNVEILING THE IMPACT OF AIR CHANGE RATES ON PARTICLE DISPERSION IN PATIENT WARDS. , DOI: https://doi.org/10.11113/jm.v48.609.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2025
Authors
7
Datasets
0
Total Files
0
DOI
https://doi.org/10.11113/jm.v48.609
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access