0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessNew-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). Sixty-five consecutive patients underwent TAVI with continuous 12-lead ECG analysis. New CAs were defined by the occurrence of LBBB, RBBB, and/or AV3B after the following pre-defined time points: (i) crossing of valve with stiff wire, (ii) positioning of balloon catheter in the aortic annulus, (iii) balloon valvuloplasty, (iv) positioning of MCS in the left ventricular outflow tract (LVOT), (v) expansion of MCS, (vi) removal of all catheters. A new CA occurred during TAVI in 48 patients (74%) and after TAVI in 5 (8%). Of the 48 patients with procedural CAs, a single new CA occurred in 43 patients (90%) and two types of CAs in 5 (10%). A new LBBB was seen in 40 patients (83%), AV3B in 9 (19%), and RBBB in 4 (8%). The new CA first occurred—in descending order of frequency—after balloon valvuloplasty in 22 patients (46%), MCS expansion in 14 (29%), MCS positioning in 6 (12%), positioning of balloon catheter in 3 (6%), wire-crossing of aortic valve in 2 (4%), and after catheter removal in 1 patient (2%). Patients who developed a new CA during balloon valvuloplasty had a significantly higher balloon/annulus ratio than those who did not (1.10 ± 0.10 vs. 1.03 ± 0.11, P = 0.030). No such relationship was found with the valve/annulus ratio. Transcatheter aortic valve implantation with the MCS was associated with new CAs in 82% of which more than half occurred before the actual valve implantation. It remains to be elucidated by dedicated studies whether new CAs can be reduced by appropriate balloon sizing—a precept that also holds for valve size given the observed directional signal of the valve size/aortic annulus ratio.
Rutger Nuis, Nicolas M. Van Mieghem, Carl Schultz, Apostolos Tzikas, Robert M. van der Boon, Anne‐Marie Maugenest, Jin Cheng, Nicolò Piazza, Ron T. van Domburg, Patrick W. Serruys, Peter P. de Jaegere (2011). Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis. European Heart Journal, 32(16), pp. 2067-2074, DOI: 10.1093/eurheartj/ehr110.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2011
Authors
11
Datasets
0
Total Files
0
Language
English
Journal
European Heart Journal
DOI
10.1093/eurheartj/ehr110
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access