0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBioresorbable scaffolds were designed to provide clinical benefits after their complete bioresorption. Prior studies demonstrated early risks with the Absorb polymeric bioresorbable vascular scaffold (BVS). Whether this risk profile changes over time during the course of its bioresorption is unknown.To examine outcomes of the first-generation BVS before and after 3 years, the point of its complete bioresorption in animals.We searched MEDLINE and the Cochrane database, conference proceedings, and public websites for relevant studies.Eligible studies were randomized clinical trials of BVS vs metallic drug-eluting stents in patients with coronary artery disease with at least 5-year follow-up. Four trials of BVS vs everolimus-eluting stents (EES) with 3384 patients met criteria.Individual patient data from the 4 trials were pooled, and summary-level meta-analysis was performed.The major effectiveness and safety measures were target lesion failure (TLF; cardiac death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization) and device thrombosis. Outcomes were examined through 5-year follow-up and between 0 to 3 and 3 to 5 years.Mean age for the 3384 patients was 62.8 years; 2452 patients were men (72.5%), and diabetes was present in 1020 patients (30.2%). Through 5-year follow-up, treatment with BVS compared with EES was associated with higher rates of TLF (14.9% vs 11.6%; HR, 1.26; 95% CI, 1.03-1.54; P = .03) and device thrombosis (2.5% vs 0.8%; HR, 2.87; 95% CI, 1.46-5.65; P = .002). Target lesion failure occurred in 11.6% of BVS-treated patients vs 7.9% of EES-treated patients between 0 to 3 years (HR, 1.42; 95% CI, 1.12-1.80), and 4.3% of BVS-treated patients vs 4.5% of EES-treated patients between 3 to 5 years (HR, 0.92; 95% CI, 0.64-1.31) (P for interaction = .046). Device thrombosis occurred in 2.4% of BVS-treated patients vs 0.6% of EES-treated patients between 0 to 3 years (HR, 3.86; 95% CI, 1.75-8.50) and 0.1% of BVS-treated patients vs 0.3% of EES-treated patients between 3 to 5 years (HR, 0.44; 95% CI, 0.07-2.70) (P for interaction = .03). These results were consistent by spline analysis and after multiple imputation and multivariable analysis.The period of excess risk for the first-generation Absorb BVS ends at 3 years. These data provide mechanistic insights into the timing of adverse events after BVS and identify the hurdles to be overcome for bioresorbable technology to be accepted as a valid alternative for patients with coronary artery disease.ClinicalTrials.gov identifiers: NCT01751906, NCT01844284, NCT01923740, and NCT01425281.
Gregg W. Stone, Takeshi Kimura, Runlin Gao, Dean J. Kereiakes, Stephen G. Ellis, Yoshinobu Onuma, Bernard Chevalier, Charles A. Simonton, Ovidiu Dressler, Aaron Crowley, Ziad A. Ali, Patrick W. Serruys (2019). Time-Varying Outcomes With the Absorb Bioresorbable Vascular Scaffold During 5-Year Follow-up. JAMA Cardiology, 4(12), pp. 1261-1261, DOI: 10.1001/jamacardio.2019.4101.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2019
Authors
12
Datasets
0
Total Files
0
Language
English
Journal
JAMA Cardiology
DOI
10.1001/jamacardio.2019.4101
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access