0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessObjectives The aim of this study was to evaluate the effect of variable dose and release kinetics of paclitaxel on neointimal hyperplasia. Background Conventional paclitaxel-eluting stents use a durable polymer coating as a vehicle for drug delivery. The Conor stent (Conor Medsystems, Menlo Park, California) with intra-strut wells and erodable polymer is specifically designed for drug delivery with programmable pharmacokinetics. Methods Two hundred and forty-four patients with single vessel disease received either a bare metal Conor stent (n = 53) or one of six different release formulations that varied in dose (10 or 30 μg) and elution release kinetics (first order, zero order), direction (abluminal, luminal), and duration (5, 10, and 30 days). End points at six months (bare stent group) and at four months (eluting stent groups) were angiographic late loss and neointimal tissue volume by intravascular ultrasound and the rate of major adverse cardiac events (MACE). Results The lowest in-stent late loss (0.38 mm, p <0.01, and 0.30 mm, p <0.01) and volume obstruction (8%, p <0.01, and 5%, p <0.01) were observed with the 10-μg and 30-μg doses in the 30-day release groups respectively, whereas the highest in-stent late loss (0.88 mm), volume obstruction (26%), and restenosis rate (11.6%) were observed in the bare stent group. The overall MACE rate of the eluting stent group was 8.6%: death 0.5%, myocardial infarction 2.7%, and target lesion revascularization (TLR) 5.3%. Sub-acute thrombosis was 0.5%. The TLR rates in the two 30-day release groups were 0% and 3.4%. Conclusions This novel eluting stent platform, using an erodable polymer with complete elution of low doses of paclitaxel, is safe. The inhibition of the in-stent neointimal hyperplasia was best in the long release groups.
Patrick W. Serruys, Georgios Sianos, Alexandre Abizaid, Jiro Aoki, Peter den Heijer, Hans Bonnier, Pieter C. Smits, Dougal McClean, Stefan Verheye, Jorge Belardi, José A. Condado, Michel Pieper, Louise Gambone, Marco Bressers, Janette Symons, Eduardo Sousa, Frank Litvack (2005). The Effect of Variable Dose and Release Kinetics on Neointimal Hyperplasia Using a Novel Paclitaxel-Eluting Stent Platform. Journal of the American College of Cardiology, 46(2), pp. 253-260, DOI: 10.1016/j.jacc.2005.03.069.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2005
Authors
17
Datasets
0
Total Files
0
Language
English
Journal
Journal of the American College of Cardiology
DOI
10.1016/j.jacc.2005.03.069
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access