0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessObjectives In this study, we assess the value of sirolimus eluting stent (SES) implantation in patients with complex in-stent restenosis (ISR). Background The treatment of ISR remains a therapeutic challenge, since many pharmacological and mechanical approaches have shown disappointing results. The SESs have been reported to be effective in de-novo coronary lesions. Methods Sixteen patients with severe, recurrent ISR in a native coronary artery (average lesion length 18.4 mm) and objective evidence of ischemia were included. They received one or more 18 mm Bx VELOCITY SESs (Cordis Waterloo, Belgium). Quantitative angiographic and three-dimensional intravascular ultrasound (IVUS) follow-up was performed at four months, and clinical follow-up at nine months. Results The SES implantation (n = 26) was successful in all 16 patients. Four patients had recurrent restenosis following brachytherapy, and three patients had totally occluded vessels preprocedure. At four months follow-up, one patient had died and three patients had angiographic evidence of restenosis (one in-stent and two in-lesion). In-stent late lumen loss averaged 0.21 mm and the volume obstruction of the stent by IVUS was 1.1%. At nine months clinical follow-up, three patients had experienced four major adverse cardiac events (two deaths and one acute myocardial infarction necessitating repeat target vessel angioplasty). Conclusions The SES implantation in patients with severe ISR lesions effectively prevents neointima formation and recurrent restenosis at four months angiographic follow-up.
Muzaffer Değertekin, Evelyn Regar, Kengo Tanabe, Pieter C. Smits, Willem J. van der Giessen, Stéphane Carlier, Pim de Feyter, Jeroen Vos, David P. Foley, Jürgen Ligthart, Jeffrey J. Popma, Patrick W. Serruys (2003). Sirolimus-eluting stent for treatment of complex in-stent restenosis. Journal of the American College of Cardiology, 41(2), pp. 184-189, DOI: 10.1016/s0735-1097(02)02704-3.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2003
Authors
12
Datasets
0
Total Files
0
Language
English
Journal
Journal of the American College of Cardiology
DOI
10.1016/s0735-1097(02)02704-3
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access