0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free Access<h3>Objective</h3> To compare the reliability, sensitivity to change and feasibility of three radiographic scoring methods for hand osteoarthritis (OA). <h3>Methods</h3> Baseline, 2-year and 6-year hand radiographs of 90 patients with hand OA were read in triplicate in chronological order by three readers from different European centres using the OARSI atlas (OARSI), Kellgren–Lawrence grading scale (KL) and Verbruggen–Veys anatomical phase score (VV). Reliability was determined using intraclass correlation coefficients and smallest detectable change (SDC). Sensitivity to change was assessed by the proportion of progression above the SDC. Feasibility was reflected by the mean performance time. <h3>Results</h3> Intra- and inter-reader reliability was similar across methods. Inter-reader SDCs (% maximum score) for KL, OARSI and VV were 2.9 (3.2), 4.1 (2.9) and 2.7 (1.8) over 2 years and 3.8 (4.1), 4.6 (3.3) and 4.0 (2.5) over 6 years, respectively. KL detected a slightly higher proportion of progression. There were differences between readers, despite methods to enhance consistency. The mean performance time (SD, minutes) for KL, OARSI and VV was 4.3 (2.5), 9.3 (6.0) and 2.8 (1.5), respectively. <h3>Conclusion</h3> Methods had comparable reliability and sensitivity to change. Global methods were fastest to perform. For multicentre trials use of a central reading centre and multiple readers may minimise inter-reader variation.
J. Bijsterbosch, I.K. Haugen, C. Malines, E. Maheu, Frits R. Rosendaal, I. Watt, Françis Berenbaum, Tore K Kvien, Désirée van der Heijde, T. Huizinga, M. Kloppenburg (2011). Reliability, sensitivity to change and feasibility of three radiographic scoring methods for hand osteoarthritis. Annals of the Rheumatic Diseases, 70(8), pp. 1465-1467, DOI: 10.1136/ard.2010.143479.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2011
Authors
11
Datasets
0
Total Files
0
Language
English
Journal
Annals of the Rheumatic Diseases
DOI
10.1136/ard.2010.143479
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access