0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. Aim: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. Methods and results: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. Conclusions: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.
Ahmed Elkoumy, John Jose, Christian Juhl Terkelsen, Henrik Nissen, Sengottuvelu Gunasekaran, Mahmoud Abdelshafy, Ashok Seth, Hesham Elzomor, Sreenivas Kumar, Francesco Bedogni, Alfonso Ielasi, Shahram Arsang-Jang, Santosh Kumar Dora, Sharad Chandra, Keyur Parikh, Daniel Unić, Andreas Baumbach, Patrick W. Serruys, Osama Soliman (2023). One-Year Outcomes after Myval Implantation in Patients with Bicuspid Aortic Valve Stenosis—A Multicentre Real-World Experience. Journal of Clinical Medicine, 12(6), pp. 2398-2398, DOI: 10.3390/jcm12062398.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2023
Authors
19
Datasets
0
Total Files
0
Language
English
Journal
Journal of Clinical Medicine
DOI
10.3390/jcm12062398
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access