0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessCorticotropin releasing factor (CRF) has recently been identified, purified and shown to be a 41-amino acid polypeptide that stimulates secretion of β-endorphin and ACTH. The metabolic clearance rates (MCR) of I125-CRF and I125-Tyr°CRF were measured in cynomolgus monkeys using the pulse injection and the continuous infusion methods. Hunter-Bolton reagent was used for iodination of CRF and the chloramine-T method for Tyr°-CRF. Gel chromatography was used to separate free iodine (and radioiodinated small fragments) from iodinated CRF in plasma samples. Disappearance of I125-CRF or ll25-Tyr°-CRF could be modeled with two components (bi-exponential). Plasma half-life of I125-CRF was 17.1 + 2.44 min (mean ± SE, n=4) for the fast component and 198 ± 5.3 min for the slow component. The MCR of I125 CRF using the pulse injection technique was 0.44 ± 0.06 L/Kg/d, n=4 and the volume of distribution 213.5 jf 12 ml, n=4, roughly equal to the plasma volume. Continuous infusion of I125-CRF and of I125-Tyr°-CRF gave MCR's ranging between 2.23 − 5.08 L/Kg/d, n=4. I125-ACTH MCR, measured for comparison using the same technique, was 5−10 fold higher. Thus, the plasma half-life of CRF is longer than for all other known hypothalamic peptides and its metabolic clearance rate relatively low and considerably less than that of ACTH. Strong binding of CRF to plasma proteins may be responsible for the small volume of distribution and lower MCR values for the pulse injection method.
H. M. Schulte, George Chrousos, Philip W. Gold, Edward H. Oldfield, Janice M. Phillips, Peter J. Munson, Gordon B. Cutler, D. Lynn Loriaux (1982). METABOLIC CLEARANCE RATE AND PLASMA HALF-LIFE OF RADIOIODINATED CORTICOTROPIN RELEASING FACTOR IN A PRIMATE. , 55(5), DOI: https://doi.org/10.1210/jcem-55-5-1023.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
1982
Authors
8
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1210/jcem-55-5-1023
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access