0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessIncomplete stent apposition (ISA) has been previously documented after sirolimus-eluting stent (SES) implantation. The aim of this study was to investigate the long-term intravascular ultrasound (IVUS) findings of ISA in patients who received SES.A total of 13 patients who received SES and showed ISA at follow-up IVUS (follow-up I) were investigated. IVUS was performed on all of these patients 12 months later (follow-up II). Quantitative ISA area measurement was also performed at follow-up I and II. No vascular remodeling was observed in the vessel segment with ISA; external elastic membrane area was 19.4+/-6.6 versus 19.5+/-6.4 mm2 at follow-up I and II, respectively. There was also no significant change in external elastic membrane area between vessel segment with ISA and without ISA (+1.5% versus -3.0%, respectively; P=0.27) at late follow-up. The ISA area, either including (2.5+/-1.7 versus 3.8+/-6.3 mm2; P=NS) or excluding (2.5+/-1.8 versus 2.4+/-1.7 mm2; P=NS) a single patient with aneurysm formation, was not significantly different between follow-up I and II. One patient manifested a coronary aneurysm in the stented segment at late follow-up that was probably present at the initial follow-up but masked by thrombus. It was successfully treated with a covered stent. All patients were asymptomatic, and no patient experienced late thrombotic occlusion.Vessel dimensions and area of ISA did not change over time, except for 1 coronary aneurysm that became apparent. ISA after implantation of a SES was not associated with adverse events at late follow-up.
Muzaffer Değertekin, Patrick W. Serruys, Kengo Tanabe, Chi‐Hang Lee, J E Sousa, Antonio Colombo, Marie-Claude Morice, Jürgen Ligthart, Pim J. de Feyter (2003). Long-Term Follow-Up of Incomplete Stent Apposition in Patients Who Received Sirolimus-Eluting Stent for De Novo Coronary Lesions. Circulation, 108(22), pp. 2747-2750, DOI: 10.1161/01.cir.0000103666.25660.77.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2003
Authors
9
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/01.cir.0000103666.25660.77
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access