0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessThere is no consensus on how to measure shoulder joint laxity and results reported in the literature are not well systematized for the available shoulder arthrometer devices. This systematic review aims to summarize the results of currently available shoulder arthrometers for measuring glenohumeral laxity in individuals with healthy or injured shoulders. Searches were conducted on the PubMed, EMBASE, and Web of Science databases to identify studies that measure glenohumeral laxity with arthrometer-assisted assessment. The mean and standard deviations of the laxity measurement from each study were compared based on the type of population and arthrometer used. Data were organized according to the testing characteristics. A total of 23 studies were included and comprised 1162 shoulders. Populations were divided into 401 healthy individuals, 278 athletes with asymptomatic shoulder, and 134 individuals with symptomatic shoulder. Sensors were the most used method for measuring glenohumeral laxity and stiffness. Most arthrometers applied an external force to the humeral head or superior humerus by a manual-assisted mechanism. Glenohumeral laxity and stiffness were mostly assessed in the sagittal plane. There is substantial heterogeneity in glenohumeral laxity values that is mostly related to the arthrometer used and the testing conditions. This variability can lead to inconsistent results and influence the diagnosis and treatment decision-making.
Eluana Gomes, Renato Andrade, Cristina Valente, Jóni Nunes, Óscar Carvalho, Vítor M. Correlo, F.S. Silva, Joaquím M. Oliveira, Rui L Reis, João Espregueira‐Mendes (2023). Inconsistency in Shoulder Arthrometers for Measuring Glenohumeral Joint Laxity: A Systematic Review. , 10(7), DOI: https://doi.org/10.3390/bioengineering10070799.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2023
Authors
10
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.3390/bioengineering10070799
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access