0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessRecent transcatheter aortic valve replacement studies have raised concerns about adverse cerebrovascular events. The etiopathology of the embolized material is currently unknown.A total of 40 patients underwent transcatheter aortic valve replacement with the use of a dual filter-based embolic protection device (Montage Dual Filter System, Claret Medical, Inc). Macroscopic material liberated during the transcatheter aortic valve replacement procedure was captured in the device filter baskets in 30 (75%) patients and sent for histopathologic analysis. The captured material varied in size from 0.15 to 4.0 mm. Amorphous calcified material (size, 0.55-1.8 mm) was identified in 5 patients (17%). In 8 patients (27%), the captured material (size, 0.25-4.0 mm) contained valve tissue composed of loose connective tissue (collagen and elastic fibers) with focal areas of myxoid stroma, with or without coverage by endothelial cells and intermixed with fibrin. In another 13 (43%) patients, collagenous tissue, which may represent elements of vessel wall and valvelike structures, was identified. In 9 patients (30%), thrombotic material was intermixed with neutrophils (size, 0.15-2.0 mm). Overall, thrombotic material was found in 52% of patients, and tissue fragments compatible with aortic valve leaflet or aortic wall origin were found in 52% (21/40) of patients.Embolic debris traveling to the brain was captured in 75% of transcatheter aortic valve replacement procedures where a filter-based embolic protection device was used. The debris consisted of fibrin, or amorphous calcium and connective tissue derived most likely from either the native aortic valve leaflets or aortic wall.
Nicolas M. Van Mieghem, M.E.I. Schipper, Elena Ladich, Elham Faqiri, Robert van der Boon, Abas Randjgari, Carl Schultz, Adriaan Moelker, Robert‐Jan van Geuns, Fumiyuki Otsuka, Patrick W. Serruys, Renu Virmani, Peter P. de Jaegere (2013). Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement. Circulation, 127(22), pp. 2194-2201, DOI: 10.1161/circulationaha.112.001091.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2013
Authors
13
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/circulationaha.112.001091
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access