0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessAbstract Pulse wave carries comprehensive information regarding the human cardiovascular system (CS), which is essential for directly capturing CS parameters. More importantly, cuffless blood pressure (BP) is one of the most critical markers in CS. Accurately measuring BP via the pulse wave for continuous and noninvasive diagnosis of a disease associated with hypertension remains a challenge and highly desirable. Here, a flexible weaving constructed self‐powered pressure sensor (WCSPS) is reported for measurement of the pulse wave and BP in a noninvasive manner. The WCSPS holds an ultrasensitivity of 45.7 mV Pa −1 with an ultrafast response time of less than 5 ms, and no performance degradation is observed after up to 40 000 motion cycles. Furthermore, a low power consumption sensor system is developed for precisely monitoring pulse wave from the fingertip, wrist, ear, and ankles. A practical measurement is performed with 100 people with ages spanning from 24 to 82 years and different health statuses. The discrepancy between the measured BP results using the WCSPS and that provided by the commercial cuff‐based device is about 0.87–3.65%. This work demonstrates an efficient and cost‐effective way for human health monitoring, which would be a competitive alternative to current complex cardiovascular monitoring systems.
Keyu Meng, Jun Chen, Xiaoshi Li, Yufen Wu, Wenjing Fan, Zhihao Zhou, Qiang He, Xue Wang, Xing Fan, Yuxin Zhang, Jin Yang, Zhong Lin Wang (2018). Flexible Weaving Constructed Self‐Powered Pressure Sensor Enabling Continuous Diagnosis of Cardiovascular Disease and Measurement of Cuffless Blood Pressure. , 29(5), DOI: https://doi.org/10.1002/adfm.201806388.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2018
Authors
12
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1002/adfm.201806388
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access