Raw Data Library
About
Aims and ScopeAdvisory Board Members
More
Who We Are?
User Guide
Green Science
​
​
Sign inGet started
​
​

About
Aims and ScopeAdvisory Board Members
More
Who We Are?
User GuideGreen Science

Sign inGet started
RDL logo

Verified research datasets. Instant access. Built for collaboration.

Navigation

About

Aims and Scope

Advisory Board Members

More

Who We Are?

Add Raw Data

User Guide

Legal

Privacy Policy

Terms of Service

Support

Got an issue? Email us directly.

Email: info@rawdatalibrary.netOpen Mail App
​
​

© 2025 Raw Data Library. All rights reserved.
PrivacyTerms
  1. Raw Data Library
  2. /
  3. Publications
  4. /
  5. Endothelial-dependent vasomotion in a coronary segment treated by ABSORB everolimus-eluting bioresorbable vascular scaffold system is related to plaque composition at the time of bioresorption of the polymer: indirect finding of vascular reparative therapy?

Verified authors • Institutional access • DOI aware
50,000+ researchers120,000+ datasets90% satisfaction
Article
English
2012

Endothelial-dependent vasomotion in a coronary segment treated by ABSORB everolimus-eluting bioresorbable vascular scaffold system is related to plaque composition at the time of bioresorption of the polymer: indirect finding of vascular reparative therapy?

0 Datasets

0 Files

English
2012
European Heart Journal
Vol 33 (11)
DOI: 10.1093/eurheartj/ehr466

Get instant academic access to this publication’s datasets.

Create free accountHow it works

Frequently asked questions

Is access really free for academics and students?

Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.

How is my data protected?

Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.

Can I request additional materials?

Yes, message the author after sign-up to request supplementary files or replication code.

Advance your research today

Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.

Get free academic accessLearn more
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaboration
Access Research Data

Join our academic network to download verified datasets and collaborate with researchers worldwide.

Get Free Access
Institutional SSO
Secure
This PDF is not available in different languages.
No localized PDFs are currently available.
Patrick W. Serruys
Patrick W. Serruys

Imperial College London

Verified
Salvatore Brugaletta
Jung Ho Heo
Héctor M. García‐García
+14 more

Abstract

To analyse the vasoreactivity of a coronary segment, previously scaffolded by the ABSORB bioresorbable vascular scaffold (BVS) device, in relationship to its intravascular ultrasound-virtual histology (IVUS-VH) composition and reduction in greyscale echogenicity of the struts. Coronary segments, transiently scaffolded by a polymeric device, may in the long-term recover a normal vasomotor tone. Recovery of a normal endothelial-dependent vasomotion may be enabled by scaffold bioresorption, composition of the underlying tissue, or a combination of both mechanisms.All patients from the ABSORB Cohort A and B trials, who underwent a vasomotion test and IVUS-VH investigation at 12 and 24 months, were included. Acetylcholine (Ach) and nitroglycerin were used to test either the endothelial-dependent or -independent vasomotion of the treated segment. Changes in polymeric strut echogenicity-a surrogate for bioresorption-IVUS-VH composition of the tissue underneath the scaffold and their relationship with the pharmacologically induced vasomotion were all evaluated. Overall, 26 patients underwent the vasomotion test (18 at 12 and 8 at 24 months). Vasodilatory response to Ach was quantitatively associated with larger reductions over time in polymeric strut echogenicity (y= -0.159x- 6.85; r= -0.781, P< 0.001). Scaffolded segments with vasoconstriction to Ach had larger vessel areas (14.37 ± 2.50 vs. 11.85 ± 2.54 mm(2), P= 0.030), larger plaque burden (57.31 ± 5.96 vs. 49.09 ± 9.10%, P= 0.018), and larger necrotic core (NC) areas [1.39 (+1.14, +1.74) vs. 0.78 mm(2) (+0.20, +0.98), P= 0.006] compared with those with vasodilation.Vasodilatory response to Ach, in coronary segments scaffolded by the ABSORB BVS device, is associated with a reduction in echogenicity of the scaffold over time, and a low amount of NC. In particular, the latter finding resembles the behaviour of a native coronary artery not caged by an intracoronary device.

How to cite this publication

Salvatore Brugaletta, Jung Ho Heo, Héctor M. García‐García, Vasim Farooq, Robert‐Jan van Geuns, Bernard De Bruyne, Dariusz Dudek, Pieter C. Smits, Jacques Koolen, Dougal McClean, Cécile Dorange, Susan Veldhof, Richard Rapoza, Yoshinobu Onuma, Nico Bruining, John A. Ormiston, Patrick W. Serruys (2012). Endothelial-dependent vasomotion in a coronary segment treated by ABSORB everolimus-eluting bioresorbable vascular scaffold system is related to plaque composition at the time of bioresorption of the polymer: indirect finding of vascular reparative therapy?. European Heart Journal, 33(11), pp. 1325-1333, DOI: 10.1093/eurheartj/ehr466.

Related publications

Why join Raw Data Library?

Quality

Datasets shared by verified academics with rich metadata and previews.

Control

Authors choose access levels; downloads are logged for transparency.

Free for Academia

Students and faculty get instant access after verification.

Publication Details

Type

Article

Year

2012

Authors

17

Datasets

0

Total Files

0

Language

English

Journal

European Heart Journal

DOI

10.1093/eurheartj/ehr466

Join Research Community

Access datasets from 50,000+ researchers worldwide with institutional verification.

Get Free Access