0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground Debate exists regarding the relationship between angiographic and intracoronary ultrasound (ICUS) measurements of minimal luminal cross-sectional area after coronary intervention. We investigated this and the factors that may influence it by using ICUS and quantitative angiography. Methods and Results Patients who underwent successful balloon angioplasty (n=100) or directional atherectomy (n=50) were examined by using ICUS and quantitative angiography (edge-detection [ED] and videodensitometry [VID]) before and after intervention. Luminal damage postintervention was qualitatively graded into three categories based on angiographic results (smooth lumen, haziness, or dissection). Correlation of minimal luminal cross-sectional area measurements by ICUS and ED was .59 before and .47 after balloon angioplasty. Correlation between ICUS and VID was .50 before and .63 after balloon angioplasty. Postintervention, the difference between ICUS and VID was less than the difference between ICUS and ED ( P <.01). Additionally, the correlation was .74 between ICUS and ED measurements and .78 between ICUS and VID measurements in the smooth lumen group, .46 and .63, respectively, in the presence of haziness, and .26 and .46, respectively, in lesions with dissection. Similar results were obtained after directional atherectomy: the agreement between ICUS and quantitative angiography deteriorated according to the degree of vessel damage, but less so with VID than ED. Conclusions Complex morphological changes induced by intervention may contribute to discordance between the two quantitative imaging techniques. In the absence of ICUS, VID may be a complementary technique to ED in lesions with complex morphology after balloon angioplasty and directional atherectomy.
Yukio Ozaki, Andonis G. Violaris, Tadashi Kobayashi, David Keane, Edoardo Camenzind, Carlo Di Mario, Pim de Feyter, Jos R.T.C. Roelandt, Patrick W. Serruys (1997). Comparison of Coronary Luminal Quantification Obtained From Intracoronary Ultrasound and Both Geometric and Videodensitometric Quantitative Angiography Before and After Balloon Angioplasty and Directional Atherectomy. Circulation, 96(2), pp. 491-499, DOI: 10.1161/01.cir.96.2.491.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
1997
Authors
9
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/01.cir.96.2.491
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access