0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground Computerized quantitative coronary angiography (QCA) has fundamentally altered our approach to the assessment of coronary interventional techniques and strategies aimed at the prevention of recurrence and progression of stenosis. It is essential, therefore, that the performance of QCA systems, upon which much of our scientific understanding has become integrally dependent, is evaluated in an objective and uniform manner. Methods and Results We validated 10 QCA systems at core laboratories in North America and Europe. Cine films were made of phantom stenoses of known diameter (0.5 to 1.9 mm) under four experimental conditions: in vivo (coronary arteries of pigs) calibrated at the isocenter or by use of the catheter as a scaling device and in vitro with 50% contrast and 100% contrast. The cine films were analyzed by each automated QCA system without observer interaction. Accuracy and precision were taken as the mean and SD of the signed differences between the phantom stenoses, and the measured minimal luminal diameters and the correlation coefficient ( r ), the SEE, the y intercept, and the slope were derived by their linear regression. Performance of the 10 QCA systems ranged widely: accuracy, +0.07 to +0.31 mm; precision, ±0.14 to ±0.24 mm; correlation ( r ), .96 to .89; SEE, ±0.11 to ±0.16 mm; intercept, +0.08 to +0.31 mm; and slope, 0.86 to 0.64. Conclusions There is a marked variability in performance between systems when assessed over the range of 0.5 to 1.9 mm. The range of accuracy, intercept, and slope values of this report indicates that absolute measurements of luminal diameter from different multicenter angiographic trials may not be directly comparable and additionally suggests that such absolute measurements may not be directly applicable to clinical practice using an on-line QCA system with a different edge detection algorithm. Power calculations and study design of angiographic trials should be adjusted for the precision of the QCA system used to avoid the risk of failing to detect small differences in patient populations. This study may guide the fine-tuning of algorithms incorporated within each system and facilitate the maintenance of high standards of QCA for scientific studies.
David Keane, Jürgen Haase, Cornelis J. Slager, Eline Montauban van Swijndregt, Kenneth G. Lehmann, Yukio Ozaki, Carlo Di Mario, Richard L. Kirkeeide, Patrick W. Serruys (1995). Comparative Validation of Quantitative Coronary Angiography Systems. Circulation, 91(8), pp. 2174-2183, DOI: 10.1161/01.cir.91.8.2174.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
1995
Authors
9
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/01.cir.91.8.2174
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access