0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessTo determine which of the three most commonly used accelerometer models has the best intra- and interinstrument reliability using a mechanical laboratory setup. Secondly, to determine the effects that acceleration and frequency have on these reliability measures.Three experiments were performed. In the first, five each of the Actical, Actigraph, and RT3 accelerometers were placed on a hydraulic shaker plate and simultaneously accelerated in the vertical plane at varying accelerations and frequencies. Six different conditions of varying intensity were used to produce a range of accelerometer counts. Reliability was calculated using standard deviation, standard error of the measurement, coefficient of variation, and intraclass correlation coefficients. In the second and third experiments, 39 Actical and 50 Actigraph accelerometers were put through the same six conditions.Experiment 1 showed poor reliability in the RT3 (intra- and interinstrument CV > 40%). Experiments 2 and 3 clearly indicated that the Actical (CVintra = 0.5%, CVinter = 5.4%) was more reliable than the Actigraph (CVintra = 3.2%, CVinter = 8.6%). Variability in the Actical was negatively related to the acceleration of the condition, whereas no relationship was found between acceleration and reliability in the Actigraph. Variability in the Actigraph was negatively related to the frequency of the condition, whereas no relationship was found between frequency and reliability in the Actical.Of the three accelerometer models measured in this study, the Actical had the best intra- and interinstrument reliability. However, discrepant trends in the variability of Actical and Actigraph counts across accelerations and frequencies preclude the selection of a superior model. More work is needed to understand why accelerometers designed to measure the same thing behave so differently.
Dale Esliger, Mark S. Tremblay (2006). Technical Reliability Assessment of Three Accelerometer Models in a Mechanical Setup. Medicine & Science in Sports & Exercise, 38(12), pp. 2173-2181, DOI: 10.1249/01.mss.0000239394.55461.08.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2006
Authors
2
Datasets
0
Total Files
0
Language
English
Journal
Medicine & Science in Sports & Exercise
DOI
10.1249/01.mss.0000239394.55461.08
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access