0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessThere is a growing appreciation of the importance of nonlinearities in evoked responses in fMRI, particularly with the advent of event-related fMRI. These nonlinearities are commonly expressed as interactions among stimuli that can lead to the suppression and increased latency of responses to a stimulus that are incurred by a preceding stimulus. We have presented previously a model-free characterization of these effects using generic techniques from nonlinear system identification, namely a Volterra series formulation. At the same time Buxton et al. (1998) described a plausible and compelling dynamical model of hemodynamic signal transduction in fMRI. Subsequent work by Mandeville et al. (1999) provided important theoretical and empirical constraints on the form of the dynamic relationship between blood flow and volume that underpins the evolution of the fMRI signal. In this paper we combine these system identification and model-based approaches and ask whether the Balloon model is sufficient to account for the nonlinear behaviors observed in real time series. We conclude that it can, and furthermore the model parameters that ensue are biologically plausible. This conclusion is based on the observation that the Balloon model can produce Volterra kernels that emulate empirical kernels. To enable this evaluation we had to embed the Balloon model in a hemodynamic input-state-output model that included the dynamics of perfusion changes that are contingent on underlying synaptic activation. This paper presents (i) the full hemodynamic model (ii), how its associated Volterra kernels can be derived, and (iii) addresses the model's validity in relation to empirical nonlinear characterisations of evoked responses in fMRI and other neurophysiological constraints.
Karl Friston, Andrea Mechelli, Robert Turner, C.J. Price (2000). Nonlinear Responses in fMRI: The Balloon Model, Volterra Kernels, and Other Hemodynamics. NeuroImage, 12(4), pp. 466-477, DOI: 10.1006/nimg.2000.0630.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2000
Authors
4
Datasets
0
Total Files
0
Language
English
Journal
NeuroImage
DOI
10.1006/nimg.2000.0630
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access