0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground Bioresorbable Vascular Scaffolds (BVS) were introduced to overcome some of the limitations of drug-eluting stent (DES) for PCI. Data regarding the clinical outcomes of the BVS versus DES beyond 2 years are emerging. Objective To study mid-term outcomes. Methods We searched online databases (PubMed/Medline, Embase, CENTRAL), several websites, meeting presentations and scientific session abstracts until August 8th, 2017 for studies comparing Absorb BVS with second-generation DES. The primary outcome was target lesion failure (TLF). Secondary outcomes were all-cause mortality, myocardial infarction, target lesion revascularization (TLR) and definite/probable device thrombosis. Odds ratios (ORs) with 95% confidence intervals (CIs) were derived using a random effects model. Results Ten studies, seven randomized controlled trials and three propensity-matched observational studies, with a total of 7320 patients (BVS n = 4007; DES n = 3313) and a median follow-up duration of 30.5 months, were included. Risk of TLF was increased for BVS-treated patients (OR 1.34 [95% CI: 1.12–1.60], p = 0.001, I2 = 0%). This was also the case for all myocardial infarction (1.58 [95% CI: 1.27–1.96], p<0.001, I2 = 0%), TLR (1.48 [95% CI: 1.19–1.85], p<0.001, I2 = 0%) and definite/probable device thrombosis (of 2.82 (95% CI: 1.86–3.89], p<0.001 and I2 = 40.3%). This did not result in a difference in all-cause mortality (0.78 [95% CI: 0.58–1.04], p = 0.09, I2 = 0%). OR for very late (>1 year) device thrombosis was 6.10 [95% CI: 1.40–26.65], p = 0.02). Conclusion At mid-term follow-up, BVS was associated with an increased risk of TLF, MI, TLR and definite/probable device thrombosis, but this did not result in an increased risk of all-cause mortality.
Cordula Felix, Victor J. van den Berg, Sanne E. Hoeks, Jiang Ming Fam, Mattie Lenzen, Eric Boersma, Peter Smits, Patrick W. Serruys, Yoshinobu Onuma, Robert‐Jan van Geuns (2018). Mid-term outcomes of the Absorb BVS versus second-generation DES: A systematic review and meta-analysis. PLoS ONE, 13(5), pp. e0197119-e0197119, DOI: 10.1371/journal.pone.0197119.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2018
Authors
10
Datasets
0
Total Files
0
Language
English
Journal
PLoS ONE
DOI
10.1371/journal.pone.0197119
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access