0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessObjectives This study sought to investigate whether the everolimus-eluting stent (EES) is superior to the paclitaxel-eluting stent (PES) with respect to long-term individual clinical outcomes. Background Individual studies have indicated a clinical advantage of coronary EES compared with PES with respect to restenosis and the composite endpoint of major adverse cardiac events. However, these trials were not powered for superiority in low-frequency event rates and have reported limited data beyond 1-year follow-up. Methods We conducted a meta-analysis of the final 3-year results from the international SPIRIT (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) II, III, and IV clinical trials. Individual patient data from 4,989 patients who were prospectively randomized to treatment with EES (n = 3,350) or PES (n = 1,639) were pooled for analysis. Results At 3-year follow-up, EES was superior to PES in reducing the following event rates: target lesion failure (8.9% vs. 12.5%, hazard ratio [HR]: 0.71, 95% confidence interval [CI]: 0.59 to 0.85; p = 0.0002), all-cause mortality (3.2% vs 5.1%, HR: 0.65, 95% CI: 0.49 to 0.86; p = 0.003), myocardial infarction (3.2% vs. 5.1%, HR: 0.64, 95% CI: 0.48 to 0.85; p = 0.002), cardiac death or myocardial infarction (4.4% vs. 6.3%, HR: 0.70, 95% CI: 0.54 to 0.90; p = 0.005), ischemia-driven target lesion revascularization (6.0% vs. 8.2%, HR: 0.72, 95% CI: 0.58 to 0.90; p = 0.004), stent thrombosis (0.7% vs. 1.7%, HR: 0.45, 95% CI: 0.26 to 0.78; p = 0.003), and major adverse cardiac events (9.4% vs. 13.0%, HR: 0.71, 95% CI: 0.60 to 0.85; p = 0.0002). No interaction was present between stent type and the 3-year relative rates of target lesion failure across a broad range of subgroups, with the exception of diabetes and vessel (left anterior descending vs. other). Conclusions In this large dataset with 3-year follow-up, coronary implantation of EES compared with PES resulted in reduced rates of all-cause mortality, myocardial infarction, ischemia-driven target lesion revascularization, stent thrombosis, and target lesion failure. Further research is warranted to characterize possible interactions between stent type, diabetes, and vessel.
George Dangas, Patrick W. Serruys, Dean J. Kereiakes, James Hermiller, Ali A. Rizvi, William Newman, Krishnankutty Sudhir, Robert S. Smith, Sherry Cao, Kleanthis Theodoropoulos, Donald E. Cutlip, Alexandra J. Lansky, Gregg W. Stone (2013). Meta-Analysis of Everolimus-Eluting Versus Paclitaxel-Eluting Stents in Coronary Artery Disease. КАРДИОЛОГИЯ УЗБЕКИСТАНА, 6(9), pp. 914-922, DOI: 10.1016/j.jcin.2013.05.005.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2013
Authors
13
Datasets
0
Total Files
0
Language
English
Journal
КАРДИОЛОГИЯ УЗБЕКИСТАНА
DOI
10.1016/j.jcin.2013.05.005
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access