0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground —Treatment of in-stent restenosis presents a critical limitation of intracoronary stent implantation. Ionizing radiation has been shown to decrease neointimal formation within stents in animal models and in initial clinical trials. We studied the effects of intracoronary γ-radiation therapy versus placebo on the clinical and angiographic outcomes of patients with in-stent restenosis. Methods and Results —One hundred thirty patients with in-stent restenosis underwent successful coronary intervention and were then blindly randomized to receive either intracoronary γ-radiation with 192 Ir (15 Gy) or placebo. Four independent core laboratories blinded to the treatment protocol analyzed the angiographic and intravascular ultrasound end points of restenosis. Procedural success and in-hospital and 30-day complications were similar among the groups. At 6 months, patients assigned to radiation therapy required less target lesion revascularization and target vessel revascularization (9 [13.8%] and 17 [26.2%], respectively) compared with patients assigned to placebo (41 [63.1%, P =0.0001] and 44 [67.7%, P =0.0001], respectively). Binary angiographic restenosis was lower in the irradiated group (19% versus 58% for placebo, P =0.001). Freedom from major cardiac events was lower in the radiation group (29.2% versus 67.7% for placebo, P <0.001). Conclusions —Intracoronary γ-radiation used as adjunct therapy for patients with in-stent restenosis significantly reduces both angiographic and clinical restenosis.
Ron Waksman, R. Larry White, Rosanna Chan, Bill Bass, Lisa Geirlach, Gary S. Mintz, Lowell F. Satler, Roxana Mehran, Patrick W. Serruys, Alexandra J. Lansky, Peter J. Fitzgerald, Balram Bhargava, Kenneth M. Kent, Augusto D. Pichard, Martin B. Leon (2000). Intracoronary γ-Radiation Therapy After Angioplasty Inhibits Recurrence in Patients With In-Stent Restenosis. Circulation, 101(18), pp. 2165-2171, DOI: 10.1161/01.cir.101.18.2165.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2000
Authors
15
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/01.cir.101.18.2165
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access