0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessThe maximum gas temperature below the ceiling is an important parameter for tunnel safety. The present study analyzed the characteristics of the maximum excess ceiling gas temperature driven by double fire sources in a naturally ventilated tunnel. A series of small-scale tunnel fire experiments were carried out with different fire separation distances and heat release rates. Theoretical analysis based on the equivalent virtual origin was also performed. The results showed that there exists only one peak gas temperature when the two fire plumes are merged before reaching the ceiling, while two peak gas temperatures can be observed when the two fire plumes are completely separated. The maximum excess gas temperature below the tunnel ceiling gradually decreases with an increasing fire separation distance in the plume merging region (S < Scp). When the fire separation distance increases further (S > Scp), the effect of the fire separation distance on the maximum gas temperature below the ceiling is very limited. Furthermore, a model using an equivalent fire source was proposed to predict the maximum excess gas temperature below the ceiling, considering different plume merging states. The present study contributes to the understanding of the maximum excess gas temperature characteristics of the smoke flow driven by double fires with an equal heat release rate in naturally ventilated tunnels.
Kun He, Ying Zhen Li, Haukur Ingason, Long Shi, Xudong Cheng (2023). Experimental study on the maximum ceiling gas temperature driven by double fires in a tunnel with natural ventilation. Tunnelling and Underground Space Technology, 144, pp. 105550-105550, DOI: 10.1016/j.tust.2023.105550.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2023
Authors
5
Datasets
0
Total Files
0
Language
English
Journal
Tunnelling and Underground Space Technology
DOI
10.1016/j.tust.2023.105550
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access