0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessAn experimental investigation into the structural performance of wire arc additively manufactured (WAAM) steel single-lap shear bolted connections is presented in this paper. The steel wire had a nominal yield stress of 420 MPa. Sixty specimens of different thicknesses, printing strategies and geometric features including end distances and plate widths were tested and analysed. The shear-out, net section tension fracture, localised tearing and curl-bearing failure modes were observed and discussed, while end-splitting was also evident. Digital image correlation (DIC) was used for detailed monitoring and visualisation of the surface strain fields that developed during testing, providing valuable insight into the developed failure mechanisms. The experimental results, which generally followed the anticipated trends, were used to assess the applicability of current design specifications developed for conventional steel bolted connections to WAAM steel bolted connections. It was found that both the cold-formed steel specifications (AISI S100 and AS/NZS 4600) and the structural steel specifications (AISC 360 and EN 1993-1) devised for conventionally manufactured steel elements, could yield considerable overestimations and underestimations of the test capacities, depending on the geometry. The overestimations are caused by shortcomings in the existing design provisions for out-of-plane failure modes, which are particularly prevalent among WAAM steel connections due to their material ductility and surface undulations, which promote curling. The underestimations relate primarily to the conservatism of the shear-out provisions. Further research is underway to underpin the development of improved design provisions.
Xi Guo, Pinelopi Kyvelou, Jun Ye, Lip H. Teh, Leroy Gardner (2022). Experimental investigation of wire arc additively manufactured steel single-lap shear bolted connections. , 181, DOI: https://doi.org/10.1016/j.tws.2022.110029.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2022
Authors
5
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1016/j.tws.2022.110029
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access