0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free Access<h3>BACKGROUND</h3> Expiratory flow rate, soft palate closure, and dead space air may influence exhaled levels of nitric oxide (NO). These factors have not been evaluated in the reservoir collection of NO. <h3>METHODS</h3> Exhaled NO was collected into a reservoir during a single flow and pressure controlled exhalation. <h3>RESULTS</h3> NO collected in a reservoir containing silica gel was stable for 24 hours. Nasally delivered 4.8% argon measured by mass spectrometry did not contaminate exhaled argon levels (0.1 (0.02)%) in five volunteers during exhalation against a resistance (10 (0.5) cmH<sub>2</sub>O), hence proving an effective soft palate closure. Exhaled NO in the reservoir was 11 (0.2) ppb, 8.6 (0.1) ppb, 7.1 (0.6) ppb, and 6.6 (0.4) ppb in five normal subjects and 48.3 (18) ppb, 20.3 (12) ppb, 16.9 (0.3) ppb and 10.1 (0.4) ppb in 10 asthmatic subjects at four studied expiratory flows (5–6, 7–8, 10–11, and 12–13 l/min, respectively), with NO levels equal to direct measurement (7.3 (0.5) ppb and 17.4 (0.5) ppb for normal and asthmatic subjects respectively, p<0.05) at the flow rate 10–11 l/min. Elimination of dead space proved necessary to provide NO levels comparable to the direct measurement. Exhaled NO collected into the reservoir without dead space during flow controlled exhalation against mild resistance provided close agreement (mean (SD) difference –0.21 (0.68), coefficient of variation 4.58%) with direct measurement in 74 patients (NO range 1–69 ppb). <h3>CONCLUSIONS</h3> Flow and pressure controlled collection of exhaled NO into a reservoir with silica gel provides values identical to the direct measurement and may be used to monitor asthma at home and where analysers are not on site.
Paolo Paredi, Stelios Loukides, S Ward, D. Cramer, Maureen Spicer, Sergei A. Kharitonov, Peter J Barnes (1998). Exhalation flow and pressure-controlled reservoir collection of exhaled nitric oxide for remote and delayed analysis. , 53(9), DOI: https://doi.org/10.1136/thx.53.9.775.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
1998
Authors
7
Datasets
0
Total Files
0
Language
en
DOI
https://doi.org/10.1136/thx.53.9.775
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access