Get Free AccessBackground— Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. Methods and Results— Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I 2 =38.40) but not in the other comparisons. Conclusions— Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography. Clinical Trial Registration— http://www.clinicaltrials.gov . Unique identifier: NCT00389220, NCT00617084.
Juan Luis Gutiérrez‐Chico, Evelyn Regar, Eveline Nüesch, Takayuki Okamura, Joanna J. Wykrzykowska, Carlo Di Mario, Stephan Windecker, Gerrit‐Anne van Es, Pierre Gobbens, Peter Jüni, Patrick W. Serruys (2011). Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents. Circulation, 124(5), pp. 612-623, DOI: 10.1161/circulationaha.110.014514.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2011
Authors
11
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/circulationaha.110.014514
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access