0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessObjectives This study sought to understand the physiological basis of baseline distal-to-aortic pressure ratio (Pd/Pa) and fractional flow reserve (FFR) agreement and discordance, using coronary flow reserve (CFR), stenosis resistance, and microcirculatory resistance measurements, and form there, to investigate the potential value of combining Pd/Pa with FFR in the diagnostic rationale. Background Pd/Pa is always available before FFR assessment, and emerging data supports the notion that baseline indices can determine the ischemic potential of coronary stenosis in selected subsets. Methods A total of 467 stenosed vessels from 363 patients were investigated with pressure and flow sensors during baseline and hyperemia: 168 vessels (135 patients) with thermodilution-derived flow, and 299 vessels (228 patients) with Doppler-derived flow. Results Pd/Pa correlated more strongly with CFR than FFR (ρ difference = 0.129; p for ρ comparison <0.001). Although Pd/Pa and FFR were closely correlated (ρ = 0.798; 95% confidence interval: 0.767 to 0.828), categorical discordance was observed in 19.3% of total vessels. Such discordance was associated with the patients’ clinical profile and was characterized by contrastive changes in stenosis resistance, microcirculatory resistance, and the underlying CFR. Notably, all stenosis with Pd/Pa ≤0.83 (n = 74, 15.8%) progressed to FFR ≤0.80, and although no Pd/Pa cutoff was able to exclude the development of FFR ≤0.80 in the high end of values, only 15 (10.1%) vessels with Pd/Pa ≥0.96 (n = 149, 31.9%) developed FFR ≤0.80, from which none had definite ischemia, as defined by CFR ≤1.74. Conclusions Combining baseline Pd/Pa with FFR seems to provide a more comprehensive physiological examination of stenosed coronary arteries and a closer pressure-based appraisal of the flow reserve of the downstream myocardial bed.
Mauro Echavarría‐Pinto, Tim P. van de Hoef, Martijn A. van Lavieren, Sukhjinder Nijjer, Borja Ibáñez, Stuart J. Pocock, Alicia Quirós, Justin E. Davies, Martijn Meuwissen, Patrick W. Serruys, Carlos Macaya, Jan J. Piek, Javier Escaned (2015). Combining Baseline Distal-to-Aortic Pressure Ratio and Fractional Flow Reserve in the Assessment of Coronary Stenosis Severity. КАРДИОЛОГИЯ УЗБЕКИСТАНА, 8(13), pp. 1681-1691, DOI: 10.1016/j.jcin.2015.09.002.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2015
Authors
13
Datasets
0
Total Files
0
Language
English
Journal
КАРДИОЛОГИЯ УЗБЕКИСТАНА
DOI
10.1016/j.jcin.2015.09.002
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access