RDL logo
About
Aims and ScopeAdvisory Board Members
More
Who We Are?
User Guide
​
​
Sign inGet started
​
​

About
Aims and ScopeAdvisory Board Members
More
Who We Are?
User Guide

Sign inGet started
RDL logo

Verified research datasets. Instant access. Built for collaboration.

Navigation

About

Aims and Scope

Advisory Board Members

More

Who We Are?

Add Raw Data

User Guide

Legal

Privacy Policy

Terms of Service

Support

Got an issue? Email us directly.

Email: info@rawdatalibrary.netOpen Mail App
​
​

© 2025 Raw Data Library. All rights reserved.
PrivacyTerms
  1. Raw Data Library
  2. /
  3. Publications
  4. /
  5. Combining Baseline Distal-to-Aortic Pressure Ratio and Fractional Flow Reserve in the Assessment of Coronary Stenosis Severity

Verified authors • Institutional access • DOI aware
50,000+ researchers120,000+ datasets90% satisfaction
Article
English
2015

Combining Baseline Distal-to-Aortic Pressure Ratio and Fractional Flow Reserve in the Assessment of Coronary Stenosis Severity

0 Datasets

0 Files

English
2015
КАРДИОЛОГИЯ УЗБЕКИСТАНА
Vol 8 (13)
DOI: 10.1016/j.jcin.2015.09.002

Get instant academic access to this publication’s datasets.

Create free accountHow it works

Frequently asked questions

Is access really free for academics and students?

Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.

How is my data protected?

Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.

Can I request additional materials?

Yes, message the author after sign-up to request supplementary files or replication code.

Advance your research today

Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.

Get free academic accessLearn more
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaboration
Access Research Data

Join our academic network to download verified datasets and collaborate with researchers worldwide.

Get Free Access
Institutional SSO
Secure
This PDF is not available in different languages.
No localized PDFs are currently available.
Patrick W. Serruys
Patrick W. Serruys

Imperial College London

Verified
Mauro Echavarría‐Pinto
Tim P. van de Hoef
Martijn A. van Lavieren
+10 more

Abstract

Objectives This study sought to understand the physiological basis of baseline distal-to-aortic pressure ratio (Pd/Pa) and fractional flow reserve (FFR) agreement and discordance, using coronary flow reserve (CFR), stenosis resistance, and microcirculatory resistance measurements, and form there, to investigate the potential value of combining Pd/Pa with FFR in the diagnostic rationale. Background Pd/Pa is always available before FFR assessment, and emerging data supports the notion that baseline indices can determine the ischemic potential of coronary stenosis in selected subsets. Methods A total of 467 stenosed vessels from 363 patients were investigated with pressure and flow sensors during baseline and hyperemia: 168 vessels (135 patients) with thermodilution-derived flow, and 299 vessels (228 patients) with Doppler-derived flow. Results Pd/Pa correlated more strongly with CFR than FFR (ρ difference = 0.129; p for ρ comparison <0.001). Although Pd/Pa and FFR were closely correlated (ρ = 0.798; 95% confidence interval: 0.767 to 0.828), categorical discordance was observed in 19.3% of total vessels. Such discordance was associated with the patients’ clinical profile and was characterized by contrastive changes in stenosis resistance, microcirculatory resistance, and the underlying CFR. Notably, all stenosis with Pd/Pa ≤0.83 (n = 74, 15.8%) progressed to FFR ≤0.80, and although no Pd/Pa cutoff was able to exclude the development of FFR ≤0.80 in the high end of values, only 15 (10.1%) vessels with Pd/Pa ≥0.96 (n = 149, 31.9%) developed FFR ≤0.80, from which none had definite ischemia, as defined by CFR ≤1.74. Conclusions Combining baseline Pd/Pa with FFR seems to provide a more comprehensive physiological examination of stenosed coronary arteries and a closer pressure-based appraisal of the flow reserve of the downstream myocardial bed.

How to cite this publication

Mauro Echavarría‐Pinto, Tim P. van de Hoef, Martijn A. van Lavieren, Sukhjinder Nijjer, Borja Ibáñez, Stuart J. Pocock, Alicia Quirós, Justin E. Davies, Martijn Meuwissen, Patrick W. Serruys, Carlos Macaya, Jan J. Piek, Javier Escaned (2015). Combining Baseline Distal-to-Aortic Pressure Ratio and Fractional Flow Reserve in the Assessment of Coronary Stenosis Severity. КАРДИОЛОГИЯ УЗБЕКИСТАНА, 8(13), pp. 1681-1691, DOI: 10.1016/j.jcin.2015.09.002.

Related publications

Why join Raw Data Library?

Quality

Datasets shared by verified academics with rich metadata and previews.

Control

Authors choose access levels; downloads are logged for transparency.

Free for Academia

Students and faculty get instant access after verification.

Publication Details

Type

Article

Year

2015

Authors

13

Datasets

0

Total Files

0

Language

English

Journal

КАРДИОЛОГИЯ УЗБЕКИСТАНА

DOI

10.1016/j.jcin.2015.09.002

Join Research Community

Access datasets from 50,000+ researchers worldwide with institutional verification.

Get Free Access