0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessMonitoring physical activity with electronic devices that use non-volatile memory is an attractive technology as it allows the user to examine patterns in physical activity as well as total activity. A new device that may be used for such purposes is the CSA accelerometer (model #7164). The device is small(5 × 5 × 1.5 cm, 70gm) which makes it particularly useful for evaluating activity in children. The aim of this study was to examine the relationship between measured METS and the 7164 accelerometer counts/min for children (age range = 6-17 yrs.). Eighty subjects (41F, 39M) completed 3, 5min treadmill conditions (2 walking and 1 jogging). CSA counts and respiratory gas exchange measures were monitored min-by-min with average of min 4 and 5 used for analysis. 50 subjects (23F, 27M) were randomly selected as the development group and 30 subjects (18F, 12M) served as the validation group. Regression analysis was used to select the significant predictors of METS: METS = 5.6832+ 0.00093(cts/min) - 0.2613(age in yrs) (R2 = 0.83). Cross-validation results (n=30) revealed no significant difference between actual and predicted METS. Pearson r = 0.86 between actual and predicted METS (SEE = ± 1.29 METS). In conclusion, these results indicate that accelerometer counts can be used to estimate different intensities of physical activity in children.
Patty S. Freedson, John R. Sirard, Edward P. Debold, Russell R. Pate, Marsha Dowda, Stewart G. Trost, James Sallis (1997). CALIBRATION OF THE COMPUTER SCIENCE AND APPLICATIONS, INC. (CSA) ACCELEROMETER 256. Medicine & Science in Sports & Exercise, 29(Supplement), pp. 45-45, DOI: 10.1097/00005768-199705001-00256.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
1997
Authors
7
Datasets
0
Total Files
0
Language
English
Journal
Medicine & Science in Sports & Exercise
DOI
10.1097/00005768-199705001-00256
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access