0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessLow wall shear stress (WSS) increases neointimal hyperplasia (NH) in vein grafts and stents. We studied the causal relationship between WSS and NH formation in stents by locally increasing WSS with a flow divider (Anti-Restenotic Diffuser, Endoart SA) placed in the center of the stent.In 9 rabbits fed a high-cholesterol diet for 2 months to induce endothelial dysfunction, 18 stents were implanted in the right and left external iliac arteries (1 stent per vessel). Lumen diameters were measured by quantitative angiography before and after implantation and at 4-week follow-up, at which time, macrophage accumulation and interruption of the internal elastic lamina was determined. Cross sections of stent segments within the ARED (S+ARED), outside the ARED (S[minus]ARED), and in corresponding segments of the contralateral control stent (SCTRL) were analyzed. Changes in WSS induced by the ARED placement were derived by computational fluid dynamics. Computational fluid dynamics analysis demonstrated that WSS increased from 0.38 to 0.82 N/m2 in the S+ARED immediately after ARED placement. This augmentation of shear stress was accompanied by (1) lower mean late luminal loss by quantitative angiography ([minus]0.23+/-0.22 versus [minus]0.58+/-0.30 mm, P=0.02), (2) reduction in NH (1.48+/-0.58, 2.46+/-1.25, and 2.36+/-1.13 mm2, P<0.01, respectively, for S+ARED, S[minus]ARED, and SCTRL), and (3) a reduced inflammation score and a reduced injury score. Increments in shear stress did not change the relationship between injury score and NH or between inflammation score and NH.The newly developed ARED flow divider significantly increases WSS, and this local increment in WSS is accompanied by a local reduction in NH and a local reduction in inflammation and injury. The present study is therefore the first to provide direct evidence for an important modulating role of shear stress in in-stent neointimal hyperplasia.
Stéphane Carlier, Luc C.A. van Damme, Casper P. Blommerde, Jolanda J. Wentzel, Glenn van Langehove, Stephan Verheye, Mark Kockx, Michiel Knaapen, Caroline Cheng, Frank Gijsen, Dirk J. Duncker, Nikolaos Stergiopulos, Cornelis J. Slager, Patrick W. Serruys, Rob Krams (2003). Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent Implantation. Circulation, 107(21), pp. 2741-2746, DOI: 10.1161/01.cir.0000066914.95878.6d.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2003
Authors
15
Datasets
0
Total Files
0
Language
English
Journal
Circulation
DOI
10.1161/01.cir.0000066914.95878.6d
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access