0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground Software to compute angiography-derived fractional flow reserve (angio-FFR) have been validated against pressure wire–derived fractional flow reserve (PW-FFR) with an area under the receiver-operating characteristic curve (AUC) of 0.93 to 0.97. Objectives The aim of this study was to investigate diagnostic accuracies of 5 angio-FFR software/methods by an independent core lab in a prospective cohort of 390 vessels with carefully documented sites of PW-FFR and pressure wire–derived instantaneous wave-free ratio. Methods One “matcher investigator” colocalized on angiography the sites of pressure wire measurement with angio-FFR measurements and provided the same 2 optimal angiographic views and frame selection to independent analysts who were blinded to invasive physiological results and results from other software. The results were anonymized and randomly presented. The AUC of each angio-FFR was compared with 2-dimensional quantitative coronary angiography (QCA) percent diameter stenosis (%DS) using a 2-tailed paired comparison of AUC. Results All 5 software/methods yielded a high proportion of analyzable vessels (A: 100%, B: 100%, C: 92.1%, D: 99.5%, and E: 92.1%). The AUCs for predicting fractional flow reserve ≤0.8 for software A, B, C, D, E, and 2-dimensional QCA %DS were 0.75, 0.74, 0.74, 0.73, 0.73, and 0.65, respectively. The AUC for each angio-FFR was significantly greater than that for 2-dimensional QCA %DS. Conclusions This head-to-head comparison by an independent core lab demonstrated that the diagnostic accuracy of various angio-FFR software for predicting PW-FFR ≤0.80 was useful, with a higher discrimination compared with 2-dimensional QCA %DS; however, it did not reach the diagnostic accuracy previously reported in validation studies of various vendors. Therefore, the intrinsic clinical value of “angiography-derived fractional flow reserve” requires confirmation in large clinical trials.
Kai Ninomiya, Patrick W. Serruys, Nozomi Kotoku, Jinying Zhou, Shigetaka Kageyama, Shinichiro Masuda, Pruthvi C. Revaiah, Bo Wang, Xingqiang He, Tsung-Ying Tsai, Momoko Kageyama, Emelyne Sevestre, Faisal Sharif, Scot Garg, Takashi Akasaka, Javier Escaned, Manesh R. Patel, Yoshinobu Onuma (2023). Anonymous Comparison of Various Angiography-Derived Fractional Flow Reserve Software With Pressure-Derived Physiological Assessment. КАРДИОЛОГИЯ УЗБЕКИСТАНА, 16(14), pp. 1778-1790, DOI: 10.1016/j.jcin.2023.04.026.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2023
Authors
18
Datasets
0
Total Files
0
Language
English
Journal
КАРДИОЛОГИЯ УЗБЕКИСТАНА
DOI
10.1016/j.jcin.2023.04.026
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access