  5. An Analysis of Current and Electric Field Pulses Associated With Upward Negative Lightning Flashes Initiated from the Säntis Tower

Verified authors • Institutional access • DOI aware
50,000+ researchers120,000+ datasets90% satisfaction
Article
en
2018

An Analysis of Current and Electric Field Pulses Associated With Upward Negative Lightning Flashes Initiated from the Säntis Tower

0 Datasets

0 Files

en
2018
Vol 123 (8)
Vol. 123
DOI: 10.1029/2018jd028295

Get instant academic access to this publication’s datasets.

Create free accountHow it works

Frequently asked questions

Is access really free for academics and students?

Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.

How is my data protected?

Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.

Can I request additional materials?

Yes, message the author after sign-up to request supplementary files or replication code.

Advance your research today

Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.

Get free academic accessLearn more
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaboration
Access Research Data

Join our academic network to download verified datasets and collaborate with researchers worldwide.

Get Free Access
Institutional SSO
Secure
This PDF is not available in different languages.
No localized PDFs are currently available.
Hongyan Xing
Hongyan Xing

Institution not specified

Verified
Lixia He
Mohammad Azadifar‬
Farhad Rachidi
+5 more

Abstract

Abstract We present a study on the characteristics of current and electric field pulses associated with upward lightning flashes initiated from the instrumented Säntis Tower in Switzerland. The electric field was measured 15 km from the tower. Upward flashes always begin with the initial stage composed of the upward‐leader phase and the initial‐continuous‐current (ICC) phase. Four types of current pulses are identified and analyzed in the paper: (1) return‐stroke pulses, which occur after the extinction of the ICC and are preceded by essentially no‐current time intervals; (2) mixed‐mode ICC pulses, defined as fast pulses superimposed on the ICC, which have characteristics very similar to those of return strokes and are believed to be associated with the reactivation of a decayed branch or the connection of a newly created channel to the ICC‐carrying channel at relatively small junction heights; (3) “classical” M‐component pulses superimposed on the continuing current following some return strokes; and (4) M‐component‐type ICC pulses, presumably associated with the reactivation of a decayed branch or the connection of a newly created channel to the ICC‐carrying channel at relatively large junction heights. We consider a data set consisting of 9 return‐stroke pulses, 70 mixed‐mode ICC pulses, 11 classical M‐component pulses, and 19 M‐component‐type ICC pulses (a total of 109 pulses). The salient characteristics of the current and field waveforms are analyzed. A new criterion is proposed to distinguish between mixed‐mode and M‐component‐type pulses, which is based on the current waveform features. The characteristics of M‐component‐type pulses during the initial stage are found to be similar to those of classical M‐component pulses occurring during the continuing current after some return strokes. It is also found that about 41% of mixed‐mode ICC pulses were preceded by microsecond‐scale pulses occurring in electric field records some hundreds of microseconds prior to the onset of the current, very similar to microsecond‐scale electric field pulses observed for M‐component‐type ICC pulses and which can be attributed to the junction of an in‐cloud leader channel to the current‐carrying channel to ground. Classical M‐component pulses and M‐component‐type ICC pulses tend to have larger risetimes ranging from 6.3 to 430 μs. On the other hand, return‐stroke pulses and mixed‐mode ICC pulses have current risetimes ranging from 0.5 to 28 μs. Finally, our data suggest that the 8‐μs criterion for the current risetime proposed by Flache et al. is a reasonable tool to distinguish between return strokes and classical M‐components. However, mixed‐mode ICC pulses superimposed on the ICC can sometimes have considerably longer risetimes, up to about 28 μs, as observed in this study.

How to cite this publication

Lixia He, Mohammad Azadifar‬, Farhad Rachidi, Marcos Rubinstein, Vladimir A. Rakov, Vernon Cooray, D. Pavanello, Hongyan Xing (2018). An Analysis of Current and Electric Field Pulses Associated With Upward Negative Lightning Flashes Initiated from the Säntis Tower. , 123(8), DOI: https://doi.org/10.1029/2018jd028295.

Related publications

Why join Raw Data Library?

Quality

Datasets shared by verified academics with rich metadata and previews.

Control

Authors choose access levels; downloads are logged for transparency.

Free for Academia

Students and faculty get instant access after verification.

Publication Details

Type

Article

Year

2018

Authors

8

Datasets

0

Total Files

0

Language

en

DOI

https://doi.org/10.1029/2018jd028295