0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessTheoretically, bioresorbable vascular scaffolds (BVSs) may provide superior long-term results compared with permanent metallic drug-eluting stents (DESs). However, whether BVSs are as safe and effective as metallic DESs prior to complete bioresorption is unknown. ABSORB Japan was a single-blind, multicentre, active-controlled, randomized trial designed to support regulatory approval of the Absorb BVS in Japan. Eligible patients with one or two de novo lesions in different epicardial vessels were randomized at 38 Japanese sites in a 2:1 ratio to Absorb BVS vs. cobalt-chromium everolimus-eluting stents (CoCr-EESs). The primary endpoint was target lesion failure [TLF: a composite of cardiac death, myocardial infarction attributable to target vessel, or ischaemia-driven target lesion revascularization (ID-TLR)] at 12 months, powered for non-inferiority. The major secondary endpoint was angiographic in-segment late lumen loss (LLL) at 13 months. A total of 400 patients were randomized to BVSs (266 patients and 275 lesions) or CoCr-EESs (134 patients and 137 lesions). TLF through 12 months was 4.2% with BVSs and 3.8% with CoCr-EESs [difference (upper one-sided 95% confidence limit) = 0.39% (3.95%); Pnon-inferiority < 0.0001]. Definite/probable stent/scaffold thrombosis at 12 months occurred in 1.5% of the patients with both devices (P = 1.0), and ID-TLR for restenosis was infrequent (1.1% with BVSs and 1.5% with CoCr-EESs, P = 1.0). With 96.0% angiographic follow-up, in-segment LLL at 13 months was 0.13 ± 0.30 mm with BVSs and 0.12 ± 0.32 mm with CoCr-EESs [difference (upper one-sided 95% confidence limit) = 0.01 (0.07); Pnon-inferiority < 0.0001). In the ABSORB Japan randomized trial, 12-month clinical and 13-month angiographic outcomes of BVSs were comparable to CoCr-EESs. ClinicalTrials.gov, number NCT01844284.
Takeshi Kimura, Ken Kozuma, Kengo Tanabe, Sunao Nakamura, Masahisa Yamane, Toshiya Muramatsu, Shigeru Saito, Junji Yajima, Nobuhisa Hagiwara, Kazuaki Mitsudo, Jeffrey J. Popma, Patrick W. Serruys, Yoshinobu Onuma, Shih‐Wa Ying, Sherry Cao, Peter Stæhr, Wai-Fung Cheong, Hajime Kusano, Gregg W. Stone (2015). A randomized trial evaluating everolimus-eluting Absorb bioresorbable scaffolds vs. everolimus-eluting metallic stents in patients with coronary artery disease: ABSORB Japan. European Heart Journal, 36(47), pp. 3332-3342, DOI: 10.1093/eurheartj/ehv435.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2015
Authors
19
Datasets
0
Total Files
0
Language
English
Journal
European Heart Journal
DOI
10.1093/eurheartj/ehv435
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access