0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessBackground There are no data comparing sirolimus-coated balloons (SCBs [MagicTouch, Concept Medical]) to paclitaxel-coated balloons (PCBs [SeQuent Please Neo, B. Braun]) for the treatment of de novo small vessel disease (SVD). Objectives This study sought to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo SVD with a PCB or SCB. Methods This prospective, multicenter, noninferiority trial randomized 121 patients (129 SVD lesions) to treatment with an SCB or PCB, with balloon sizing determined using optical coherence tomography. The primary endpoint was noninferiority for the 6-month angiographic net lumen gain. Results Angiographic follow-up was completed in 109 (90.1%) patients in the per-protocol analysis. The mean ± SD angiographic net gains were 0.25 ± 0.40 mm with SCBs vs 0.48 ± 0.37 mm with PCBs, resulting in SCBs failing to meet the 0.30 mm criterion for noninferiority (P noninferiority = 0.173), with an absolute difference of −0.23 mm (95% CI: −0.37 to −0.09) secondary to a smaller late loss (0.00 ± 0.32 mm vs 0.32 ± 0.47 mm; P < 0.001) and more frequent late lumen enlargement (53.7% vs 30.0%; OR: 2.60; 95% CI: 1.22-5.67; P = 0.014) with PCBs. Binary restenosis rates were 32.8% and 12.5% following treatment with SCBs and PCBs, respectively (OR: 3.41; 95% CI: 1.36-9.44; P = 0.012). The mean angiography-derived fractional flow ratio at follow-up was 0.86 ± 0.15 following treatment with SCBs and 0.91 ± 0.09 following PCBs (P = 0.026); a fractional flow ratio ≤0.80 occurred in 13 and 5 vessels after treatment with SCBs and PCBs, respectively. Conclusions The SCB MagicTouch failed to demonstrate noninferiority for angiographic net lumen gain at 6 months compared to the PCB SeQuent Please Neo.
Kai Ninomiya, Patrick W. Serruys, Antonio Colombo, Bernhard Reimers, Sandeep Basavarajaiah, Faisal Sharif, Luca Testa, Carlo Di Mario, Roberto Nerla, Daixin Ding, Jiayue Huang, Nozomi Kotoku, Shigetaka Kageyama, Momoko Kageyama, Emelyne Sevestre, Simone Fezzi, Jouke Dijkstra, Neil O’Leary, Marie Angèle Morel, Scot Garg, Bernardo Cortese, Yoshinobu Onuma (2023). A Prospective Randomized Trial Comparing Sirolimus-Coated Balloon With Paclitaxel-Coated Balloon in De Novo Small Vessels. КАРДИОЛОГИЯ УЗБЕКИСТАНА, 16(23), pp. 2884-2896, DOI: 10.1016/j.jcin.2023.09.026.
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Article
Year
2023
Authors
22
Datasets
0
Total Files
0
Language
English
Journal
КАРДИОЛОГИЯ УЗБЕКИСТАНА
DOI
10.1016/j.jcin.2023.09.026
Access datasets from 50,000+ researchers worldwide with institutional verification.