0 Datasets
0 Files
Get instant academic access to this publication’s datasets.
Yes. After verification, you can browse and download datasets at no cost. Some premium assets may require author approval.
Files are stored on encrypted storage. Access is restricted to verified users and all downloads are logged.
Yes, message the author after sign-up to request supplementary files or replication code.
Join 50,000+ researchers worldwide. Get instant access to peer-reviewed datasets, advanced analytics, and global collaboration tools.
✓ Immediate verification • ✓ Free institutional access • ✓ Global collaborationJoin our academic network to download verified datasets and collaborate with researchers worldwide.
Get Free AccessAlthough solar chimney as a reliable passive renewable energy system has been widely adopted in buildings, its application in the tunnel is so far limited. By developing a validated numerical model, this study systematically investigated four critical factors that govern the effectiveness of solar chimney in tunnel applications, such as cavity height (h c),cavity gap (L),solar radiation, and fire size.It was known that the chimney height in tunnel shows a relatively higher impact on the natural ventilation whencomparedto the applications in the building, but in theopposite position for the solar radiation. The natural ventilation rate is proportional to h c 0.69 in the tunnel, but the power is between 0.5 and 2/3 for building applications. The power for solar radiation in tunnel is 0.34, where it is 0.572 for thebuilding.It was obtained from an orthogonal analysis that chimney height presents a relatively higher impact on the natural ventilation performance of a solar chimney in the tunnel, but it shows an opposite phenomenon under the smoke exhaustion model. Under both natural ventilation and smoke exhaustion modes, chimney height and cavity gap show relatively stronger influence on the performance than that from solar radiation. A theoretical model was also developed that considers both the vertically linear and horizontally parabolic temperature distributions inside the chimney cavity. The predictions when considering both distributions agree reasonably well with those numerical results, which drops about 20.6% when compared to the predictions of those traditional models without the considerations.
Xudong Cheng, Zhicheng Shi, Kate Nguyen, Lihai Zhang, Yong Zhou, Guomin Zhang, Jinhui Wang, Long Shi (2025). A case study of multifunctional solar chimney in tunnelA case study of multifunctional solar chimney in tunnel. Elsevier eBooks, pp. 225-255, DOI: 10.1016/b978-0-443-33986-8.00009-9,
Datasets shared by verified academics with rich metadata and previews.
Authors choose access levels; downloads are logged for transparency.
Students and faculty get instant access after verification.
Type
Chapter in a book
Year
2025
Authors
8
Datasets
0
Total Files
0
Language
English
DOI
10.1016/b978-0-443-33986-8.00009-9
Access datasets from 50,000+ researchers worldwide with institutional verification.
Get Free Access